September 2026 Release Notes

September 30th 2026

Advance Notice

From October 7th 2026, OPCS procedure codes that were discontinued when the standard moved from 4.10 to 4.11 will be marked as inactive in the platform. OPCS 4.10 was officially superseded on March 31, 2026, and we've been working with customers to transition to 4.11.

Assessments that already reference these discontinued codes will continue to display them. If you have ADT integrations sending these codes, they will still be accepted and processed.

For customers without procedure code integration, these codes will no longer appear in the manual selection dropdown in the clinical portal so cannot be applied to assessments after this date. If you have questions about the impact on your workflow, contact your account manager.

Improvements

ASA Grade Protection

ASA grades can no longer be automatically downgraded by form submissions.

Previously, if a clinician set an ASA grade on an assessment and then sent a form (patient or clinician-completed), the answers could trigger a lower calculated grade that would overwrite the clinician's entry, meaning the assessment could show a lower ASA grade than the clinician had set.

The system now always retains the higher of the two grades: what was already on the assessment or what is calculated from the new submission. Clinicians can still manually change an ASA grade where clinically appropriate.

This change has been rolled out to all customers. It has not been applied retrospectively, so ASA grades on existing assessments that were lowered by a form submission before this update remain unchanged. Customers may wish to consider whether any such assessments should be reviewed, for example where a clinician set the ASA grade before a form was sent or resubmitted.

ASA Grade Disabling by Product

ASA grades can now be disabled entirely for products where they are not clinically relevant, such as MyCardiology. This is configured on a per-product basis. If you want to disable ASA grades for your product, contact your account manager.

Clinical Notes History Version Tracking

The clinical notes audit dialog and PDF export now display against the form version in which the notes were saved, rather than the current form version if they differ.

Previously, the latest clinical notes history entry and PDF export were shown against the current form version regardless of when the notes were saved, so answers in fields later removed from the form did not appear. No data was lost, and earlier history entries were not affected.

A new indicator in the audit dialog tells users when the last saved version differs from the current form version. This has been rolled out to all customers. It has not been applied retrospectively, so PDFs exported before this update remain unchanged and may not include answers from fields later removed from the form. Customers may wish to consider whether any such PDFs, for example those stored in other clinical systems, should be re-exported.

Archived and Binned Assessment Attention Flags

Attention flags on assessments can now be acknowledged even when the assessment is archived or binned. This feature is in the process of being rolled out to customers and is currently available in all test portals. Remaining live portals will have access by October 12th.

Bug Fixes

  • Fixed alphabetical sorting on dashboard columns that should sort by name (Assessment Group, Tag, Specialty, and Consultant). This is a global change to all customers. No action is required.
  • Fixed an issue where the clinician link dialog or in-person code dialog would disappear when accessing a previously completed form. This is a global change to all customers. No action is required.
  • Improved the reliability and resilience of our internal queue worker services to better handle network outages. This addresses the reminder sending delays some customers experienced recently. More details are available at status.ultramed.co.